1-3-04, Dial 1 (DP) Hookflash Selection DRAFT 3 Chapter 1 – 157
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-3-04
System Mode
1
Submode
3
Data No.
04
PC Programming
+ BTI
Dial 1 (DP) Hookflash
Selection
General Description
Use this Memory Block to specify whether or not pressing 1 during an intercom call or a CO/PBX
call on a dial pulse (DP) Single Line Telephone provides a hookflash signal.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
Yes No
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 + KDto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
4-67 SLT Data Line Security Assignment
4-93 DTMF/DP SLT Type Selection