Xen IPK Programming Manual
1-2-22, Call Forward No Answer Timer Selection DRAFT 3 Chapter 1 – 143
Doc. No.: 8194 - Release 2.0
December 2004
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 01 to 99 sec
Default values:
Class 1 to Class 4 = 12 secs
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46 Access Code (1-Digit) Assignment
1-1-47 Access Code (2-Digit) Assignment
1-2-01 Intercom Call Voice/Tone Signal Selection
1-8-08 Class of Service (Station) Feature Selection 2
4-17 Station to Class of Service Feature Assignment
4-42 Call Forward-Busy Immediately/Delay Selection
4-71 Time Class Assignment for Telephone Mode (R2000 and above)
N
1. For ACD Call Forward No Answer time refer to Memory Block , 1-8-40.
2. This will effect ICM, DIT, DID, TLI calls. CO Ringing Assigned Calls do not follow this Memory Block setting.