Xen IPK Programming Manual
3-61, DIT Delay Answer Timer Selection DRAFT 3 Chapter 1 – 391
Doc. No.: 8194 - Release 2.0
December 2004
Programming Procedures
1
Go off-line.
2
Press LK3 + N + AEto access the Memory Block.
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 00 to 99 sec
(00 = Unlimited)
Default values:
Trunk 01~64 = 00 sec
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
3-63 DIT Tenant Assignment
3-64 DIT Holiday Mode Enable
3-65 DIT Night Mode Delay Answer Enable
4-71 Time Class Assignment for Telephone Mode (R2000 and above)
N
When the time is set to a value other than 0, call termination is treated as a normal incoming call and DIT termination is
performed after the time elapses. When 0 is selected, DIT call termination is performed immediately.