EasyManua.ls Logo

NEC Xen IPK - Page 66

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2004 NEC Business Solutions Ltd
46 – Chapter 1 DRAFT 3 Station Transfer/Camp-On Recall Timer Selection, 1-1-12
Doc. No.: 8194 - Release 2.0
December 2004
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 000 to 999
sec
000 = No
Limit
Default values:
Class 1 to Class 4 = 060 secs
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-11 System Transfer/Camp-On Selection
1-6-05 Attendant Add-On Console Key Selection
1-8-08 Class of Service (Station) Feature Selection 2
1-1-64 Attendant Add-On Console Transfer/Camp-On Recall Timer Selection
4-71 Time Class Assignment for Telephone Mode (R2000 and above)
N
When a station with an Attendant Add-On Console assigned to it transfers or camps on a call and the call goes
unanswered, the call recalls using Memory Block 1-1-64 Attendant Add-On Console Transfer/Camp-On Recall Timer
Selection.