CLI Commands
4.5 E
SCALANCE W1750D CLI
106 Function Manual, 03/2019, C79000-G8976-C452-04
Usage Guidelines
Use this command to assign a wired profile to the ENET 2 port to activate the wired profile.
Example
The following command assigns a wired profile to the ENET 2 port:
(scalance)(config)# enet2-port-profile <name>
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.5.7 enet4-port-profile
Description
This command assigns a wired profile to the ENET 4 port on an AP.
Syntax
enet4-port-profile <profile>
Parameter
Description
enet4-port-profile <pro-
file>
Assigns a wired profile to the ENET 4 interface port.
Usage Guidelines
Use this command to assign a wired profile to the ENET 4 port to activate the wired profile.
Example
The following command assigns a wired profile to the ENET 4 port:
(scalance)(config)# enet4-port-profile <name>
(scalance)(config)# end
(scalance)# commit apply