Description
This command configures an interval after which the authenticated credentials of the clients
stored in the cache expire. When the cache expires, the clients are required to authenticate
again.
Syntax
auth-failure-blacklist-time <seconds>
Parameter
Description
Range
Default
<seconds>
Indicates the duration after which the authenticated
credentials in the cache expire.
1-99 hours 24 hours
Usage Guidelines
Use this command when the authentication survivability is enabled on a network profile, to
set a duration after which the authentication credentials stored in the cache expires. To
enable the authentication survivability feature, use the
auth-survivability in WLAN SSID
profile sub-mode.
Example
(scalance) (config)# auth-survivability cache-time-out 60