CLI Commands
4.16 S
SCALANCE W1750D CLI
622 Function Manual, 03/2019, C79000-G8976-C452-04
no...
Parameter
Description
Range
sesimagotag-esl-
channel <channel>
Configures the static channel number of the ESL radio. 0 - 10
sesimagotag-esl-
serverip <addr>
Configures the IP address of the ESL server.
no
Removes the configuration.
Example
The following example shows how to configure SES-imagotag:
(scalance)(config) # sesimagotag-esl-profile
(scalance)(sesimagotag-esl-profile) # sesimagotag-esl-serverip 10.62.39.210
(scalance)(sesimagotag-esl-profile) # sesimagotag-esl-channel 9
(scalance)(sesimagotag-esl-profile) # end
Command Information
AP Platform
Command Mode
All platforms
Configuration mode and sesimagotag-esl-profile sub configuration mode
4.16.236 snmp-server
Description
This command configures SNMP parameters.
Syntax
snmp-server
community <address>
engine-id <engineID>
host <ipaddr> version {1 <name> udp-port <port>}|{2c|3 <name> [inform] [udp-port
<port>]}
user <name> <auth-prot> <password> <priv-prot> <password>
Parameter
Description
Range
Default
community
Sets the read-only community string.
engine-id
Sets the SNMP server engine ID as a hexadecimal num-
ber.
24 characters