226 Function Manual, 03/2019, C79000-G8976-C452-04
Example
The following example configures a management subnet;
(scalance)(config) # restricted-mgmt-access 192.0.2.13 255.255.255.255
(scalance)(config) # end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.15.7 rf-band
Description
This command configures the RF band for an AP.
Syntax
rf-band {2.4| 5.0| all}
Parameter
Description
Range
Default
rf-band {2.4|
5| all}
Configures a radio frequency band for an AP. You
can configure any of the following options:
2.4For 2.4 GHz band or 802.11g configura-
tion
5—For 5 GHz and 802.11a configuration
all - For a mixed configuration of 2.4.GHz and 5
GHz. If you do not specify any value, by default
both 5 GHz and 2.4 GHz bands are selected.
2.4, 5.0, all all
Usage Guidelines
Use this command to configure RF band for an AP.
Example
The following example configures the 5 GHz RF band for an AP.
(scalance)(config)# rf-band 5