EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Clarity

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.3 C
SCALANCE W1750D CLI
68 Function Manual, 03/2019, C79000-G8976-C452-04
4.3.3 clarity
Description
This command enables inline monitoring statistics for the Instant AP. The information is collected
and forwarded to AirWave to debug client connectivity issues.
Syntax
clarity
inline-auth-stats
inline-dhcp-stats
inline-dns-stats
inline-sta-stats
no…
Parameter
Description
Default
inline-auth-stats
Enables the client authentication statistics on the AP.
Disabled
inline-dhcp-stats
Enables the DHCP statistics on the AP. Disabled
inline-dns-stats
Enables the DNS statistics on the AP.
Disabled
inline-sta-stats
Enables the station passive monitor statistics on the
AP.
Disabled
no…
Removes the configuration and returns the values to its
default setting
Usage Guidelines
Use this command to configure the AP to generate authentication, dhcp, dns, and station
passive monitor statistics by using inline monitoring. These statistics are sent to AirWave to
derive conclusions on the client connectivity issues.
Example
The following example configures a clarity profile:
(scalance)(config)# clarity
(scalance)(clarity)# inline-auth-stats
(scalance)(clarity)# inline-dhcp-stats
(scalance)(clarity)# inline-dns-stats
(scalance)(clarity)# inline-sta-stats
(scalance)(clarity)# end
(scalance)# commit apply