EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Ble

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.2 B
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
61
Syntax
blacklist-time <seconds>
Parameter
Description
Range
<seconds>
Sets the duration in seconds for black-
listing clients due to an ACL rule trig-
ger.
3600
Usage Guidelines
Use this command to configure the duration in seconds for which the clients can be
blacklisted when the blacklisting rule is triggered.
Example
The following command configures the duration for blacklisting clients:
(scalance) (config) # blacklist-time 30
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.2.4 ble
Description
This command enables BLE beacon management by BMC and configures the BLE
operation mode.
Syntax
ble
config <token> <url>
mgmt-server <type>