CLI Commands
4.1 A
SCALANCE W1750D CLI
32 Function Manual, 03/2019, C79000-G8976-C452-04
Syntax
a-ant-pol <pol>
Parameter
Description
Range
<pol>
Denotes the antenna polarization value for 5 GHz radio channel.
0: Co-Polarized radio ID
1: Cross-Polarized radio ID
0 or 1
Usage Guidelines
Use this command to set the antenna polarization value for 5 GHz radio channel.
Example
The following example configures the antenna polarization value for a 5 GHz radio channel:
(scalance)# a-ant-pol 0
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.1.7 advanced-zone
Description
This command is used to enable or disable the advanced zone feature that can configure up
to 32 SSIDs. Since the mapping method of the WLAN index and BSSID index are different,
when you change the advanced zone configuration, the BSSID is removed and created
again.
When advanced zone is enabled:
The WLAN SSID profile will remain inactive without the zone.
Configure the AP zone. Otherwise, keep the WLAN SSIDs inactive.
A zone can be assigned to a maximum of up to 16 SSIDs. However, if the extended SSID
is disabled, a zone can be assigned to a maximum of up to 14 SSIDs wherein the first
two virtual APs are reserved for mesh.
Syntax
advanced-zone
no…