EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Ap-Frequent-Scan

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.1 A
SCALANCE W1750D CLI
48 Function Manual, 03/2019, C79000-G8976-C452-04
4.1.24 ap-frequent-scan
Description
This command enables an AP to search for a new environment, triggering the ARM profile to
perform frequent scanning of transmission signals in a short span of time. Once the frequent
scanning is complete, the ARM selects a valid channel of transmission.
Syntax
ap-frequent-scan <band>
Parameter
Description
Range
band
Sets a frequency band of the transmission signal during frequent
scanning.
NOTE:
Client connection is impacted for a few seconds when the
frequent scanning is in progress. The connection is re-established
after the scanning is complete. Typically, a frequent scanning
session lasts for less than 10 seconds.
2.4, 5.0, all
Usage Guidelines
Execute this command to enable the AP to perform frequent scanning of transmission
signals, and to select a valid channel for transmission.
The following checks must be performed before scanning:
The DFS channels are skipped.
The AP is on stand-alone mode.
The
client-aware parameter is disabled by executing the arm command.
Example
The following example triggers the ARM to perform frequent scanning on a 2.4 GHz
frequency band radio profile:
(scalance)# ap-frequent-scan 2.4
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode

Table of Contents