CLI Commands
4.18 U
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
641
4.18.3 uplink
Description
This command configures uplink connections.
Syntax
uplink
enforce {ethernet| cellular |wifi | none}
failover-internet
failover-internet-ip <ip>
failover-internet-ip-for-cellular-uplink <ip>
failover-internet-check-timeout
failover-internet-pkt-lost-cnt <count>
failover-internet-pkt-send-freq <frequency>
failover-vpn-timeout <seconds>
preemption [interval <interval>]
uplink-priority {cellular <priority> | {ethernet <priority>| [port <Interface-
number>
<priority>}|wifi <priority>}
no…
no uplink
Parameter
Description
Range
Default
uplink
Enables the uplink configuration sub-
mode.
enforce {ethernet|cellular
|wifi | none}
Enforces the specified uplink connec-
tion.
You can specify the following types of
uplink:
ethernet
cellular
wifi
none
ethernet,
cellular, wifi,
none
None

Table of Contents