EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Ip Radius

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.9 I
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
189
Command Information
AP Platform
Command Mode
All platforms Configuration mode and IPM configuration sub-
mode.
4.9.14 ip radius
Description
This command configures global parameters for configured RADIUS servers.
Syntax
ip radius rfc-3576-server udp-port <port>
Parameter
Description
Range
Default
rfc-3576-server
Configures the UDP port to receive
requests from a RADIUS server.
NOTE:
This parameter can only be
used on Virtual Controller.
udp-port
Indicates the UDP port to receive
server requests.
<port>
Indicates the port number.
1–65535
3799
Usage Guidelines
This command configures global RADIUS server parameters. The rfc3576 parameter must
be enabled in the
wlan auth-server command for the global RADIUS server configuration to
take effect.
Example
The following example configures the UDP port:
(scalance)(config)# ip radius rfc-3576-server udp-port 1700
(scalance)(config)# end
(AP )# commit apply