EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Show Gre Config

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.16 S
SCALANCE W1750D CLI
502 Function Manual, 03/2019, C79000-G8976-C452-04
The following show g-max-clients <ssid_profile> command output displays the maximum
number of clients allowed to connect to the
test1 SSID:
(scalance)# show g-max-clients test1
g-max-clients: 77
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.16.136 show gre config
Description
This command displays the various parameters configured for the GRE tunnel.
Syntax
show gre config
Usage Guidelines
Use this command to view the GRE configuration information for an AP.
Example
The following example shows the output of show gre-config command:
GRE Primary Server :pgre.arubanetworks.
GRE Primary Server :pgre.arubanetworks.com
GRE Primary IP :2000:172:16:168::1
GRE Backup Server :sgre.arubanetworks.com
GRE Backup IP :2000:172:16:168::2
GRE Type :25944 (0x6558)
GRE Per AP Tunnel :disable
GRE Preemption :enable
GRE Holdon Time :60 (secs)
GRE Failover type :ping
GRE Ping Interval :10 (secs)
GRE Allowed Inactive Time :10 (secs)

Table of Contents