CLI Commands
4.5 E
SCALANCE W1750D CLI
102 Function Manual, 03/2019, C79000-G8976-C452-04
4.5 E
4.5.1 enet-vlan
Description
This command configures a VLAN for Ethernet connections.
Syntax
enet-vlan <vlan-ID>
no…
Parameter
Description
Range
Default
enet-vlan <vlan-ID>
Configures VLAN for the upstream switch to
which the AP is connected.
0 ... 4093 1
no…
Removes the configuration. - -
Usage Guidelines
Use this command to configure VLAN settings for upstream switch to which the AP is
connected. By default, the value is set to 1. The VLAN setting configured by this command is
used for restricting the AP from sending out tagged frames to clients connected on the SSID
that has the same VLAN as the native VLAN of the upstream switch, to which the AP is
connected.
Example
The following example configures a non-default VLAN value for the Ethernet ports:
(scalance)(config)# enet-vlan 200
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode