CLI Commands
4.16 S
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
623
Parameter
Description
Range
Default
host
<ipaddr>
Configures the IP address of the host to which SNMP traps
are sent. This host needs to be running a trap receiver to
receive and interpret the traps sent by the controller.
version
Configures the SNMP version and security string for notifi-
cation messages.
1,2c,3
inform
Sends SNMP inform messages to the configured host.
udp-port
Indicates the port number to which notification messages
are sent.
162
user
Configures an SNMPv3 user profile for the specified
username.
auth-prot
Indicates the authentication protocol for the user, either
HMAC-MD5-98 Digest Authentication Protocol or HMAC-
SHA-98 Digest Authentication Protocol, and the password
touse with the designated protocol.
MD5/SHA SHA
priv-prot
Indicates the privacy protocol for the user and the pass-
wordto use with the designated protocol. CBC-DES Sym-
metric Encryption Protocol is the default option.
DES DES
Usage Guidelines
This command configures SNMP on the APs only.
Example
The following example configures an SNMP host and community string:
(scalance)(config)# snmp-server community user123
(scalance)(config)# snmp-server host 10.0.0.1 version 2c udp-port 162 inform
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.16.237 speed test
Description
This command enables the user to configure a speed test to run each time the AP boots up
and additionally configure time intervals at which it is executed periodically.
Syntax
speed-test