CLI Commands
4.18 U
SCALANCE W1750D CLI
644 Function Manual, 03/2019, C79000-G8976-C452-04
Switching Uplinks Based on Internet Availability
When the uplink switchover based on Internet availability is enabled, the AP continuously
sends ICMP packets to some well-known Internet servers. If the request is timed out due to
a bad uplink connection or uplink interface failure, and the public Internet is not reachable
from the current uplink, the AP switches to a different connection.
Example
The following example configures uplink priority:
(scalance)(uplink)# uplink-priority ethernet port 0 1
(scalance)(uplink)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms Configuration mode and uplink configuration sub-
mode.
4.18.4 uplink-vlan
Description
This command configures uplink VLAN for management traffic on an AP.
Syntax
uplink-vlan <vlan-ID>
Parameter
Description
Range
Default
<vlan-ID>
Assigns a VLAN ID for the uplink
management traffic
0-4093 0
Usage Guidelines
Use this command to configure the uplink VLAN configuration details for management traffic.
When configured, the uplink management VLAN allows you to tag management traffic and
connect multiple AP clusters to the same port on an upstream switch (for example, AirWave
server).