EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Show Pppoe

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.16 S
SCALANCE W1750D CLI
554 Function Manual, 03/2019, C79000-G8976-C452-04
-----------------------------
uplink-down
primary-uplink-down
internet-down
vpn-down
-----------
-------------------
-------------
--------
No
No
-
Yes
The following out-of-service events got triggered in last out-of-service-hold-on-
time(45) sec
: None
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.16.187 show pppoe
Description
This command shows PPPoE debug logs and uplink status.
Syntax
show pppoe {config|debug logs|debug status}
Parameter
Description
config
Displays PPPoE configuration details.
debug logs
Displays PPPoE debug logs.
debug status
Displays the uplink status.
Example
show pppoe config
The following example shows the configuration of the PPPoE
show pppoe config command.
PPPoE Configuration
-------------------
Type Value
---- -----
User user
Password d226ccefac5a95cd6bb04ca74f20473eae9085fb16892b66
Service name ServiceA
CHAP secret 8acc867926ad85681fd0b0c1a15bb818

Table of Contents

Related product manuals