show wifi-uplink status
The following output is displayed for the
show wifi-uplink status command:
configured :YES
enabled :YES
The output of this command indicates if the Wi-Fi uplink is configured and enabled on the
AP.
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.16.230 show wired-port
Description
This command displays the configuration details associated with a wired profile configured
on an AP.
Syntax
show wired-port <profile-name>
Parameter
Description
<profile-name>
Displays the current configuration details for a specific wired profile.
Usage Guidelines
This command displays the configuration details associated with a wired profile configured
on an AP.
Example
The following example shows the output of the show wired-port <profile-name> command:
Name :default_wired_port_profile
VLAN Mode :Trunk
Allowed VLANs :all
Native VLAN :1
Admin Status :Down