EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Clock Summer-Time

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.3 C
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
73
Syntax
clock set <year> <month> <day> <hour> <min> <sec>
Parameter
Description
Range
<year>
Sets the year. Requires all 4 digits.
Numeric
<month>
Sets the month. 1-12
<day>
Sets the day.
1-31
<time>
Sets the hour. Specify hours, minutes,
and seconds separated by spaces.
<hour> <min> <sec>
Numeric
Usage Guidelines
You can configure the year, month, day, and time. Specify the time using a 24-hour clock
with hours, minutes and seconds separated by spaces.
Example
The following example sets the clock to 21 May 2013, 1:03:52 AM:
(scalance)# clock set 2013 5 21 1 3 52
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.3.9 clock summer-time
Description
This command configures daylight saving for the time zones that support DST.
Syntax
clock summer-time <timezone> recurring <start-week> <start-day> <start-month> <start-
hour>
<eweek> <eday> <emonth> <ehour>
no…