CLI Commands
4.3 C
SCALANCE W1750D CLI
74 Function Manual, 03/2019, C79000-G8976-C452-04
Parameter
Description
Range
clock summer-
time
<timezone>
Configures Daylight Saving time. Timezones that sup-
port daylight saving
configuration
recurring
Indicates the recurrences.
<start-week>
Indicates the week from which the daylight saving
configuration is effective.
<start-day>
Indicates the day from which the daylight saving
configuration applies.
<start-month>
Indicates the month from which the daylight saving
configuration applies.
<start-hour>
Indicates the hour from which the daylight saving
configuration applies.
1-24
<eweek>
Indicates the week in which the daylight saving
configuration ends.
<eday>
Indicates the day on which daylight saving configuration
ends.
<emonth>
Indicates the month in which daylight saving
configuration ends.
<ehour>
Indicates the hour at which daylight saving configuration
ends.
1-24
no…
Removes the configuration
Usage Guidelines
Use this command to configure daylight saving for the timezones that support daylight
saving. When enabled, the DST ensures that the AP reflect the seasonal time changes in the
region they serve.
Example
The following example configures daylight saving for a timezone:
(scalance)(config)# clock summer-time PST recurring 7 10 March 9PM 38 10 October 9PM
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode