CLI Commands
4.1 A
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
33
Example
(scalance)(config)# advanced-zone
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.1.8 aeroscout-rtls
Description
This command configures the Aeroscout RTLS settings for Scalance W and sends the RFID
tag information to an Aeroscout RTLS server.
Syntax
aeroscout-rtls <addr> <Port> [include-unassoc-sta]
no…
Parameter
Description
Default
<addr>
IP address of the Aeroscout RTLS server to which the loca-
tion reports are sent.
<Port>
Port number of the Aeroscout RTLS server to which the
location reports are sent.
[include-unassoc-
sta]
Includes the client stations not associated to any AP when
mobile unit reports are sent to the Aeroscout RTLS server.
Disabled
no
Removes the Aeroscout RTLS configuration.
Usage Guidelines
This command allows you to integrate Aeroscout RTLS server with Scalance W by
specifying the IP address and port number of the Aeroscout RTLS server. When enabled,
the RFID tag information for the stations associated with an AP are sent to the AeroScout
RTLS. You can also send the RFID tag information for the stations that are not associated
with any AP.
Example
The following example configures the Aeroscout RTLS server:
(scalance)(config)# aeroscout-rtls 192.0.2.2 3030 include-unassoc-sta
(scalance)(config)# end
(scalance)# commit apply