CLI Commands
4.16 S
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
625
Usage Guidelines
Use this command to run a speed test on the Master AP.
Example
The following example configures the speed test profile:
(scalance)(config)# speed-test
(scalance)(speed-test)# server-ip 10.17.138.2
(scalance)(speed-test)# server-port 5201
(scalance)(speed-test)# sec-to-measure 20
(scalance)(speed-test)# include-reverse
(scalance)(speed-test)# omit 5
(scalance)(speed-test)# parallel 10
(scalance)(speed-test)# protocol udp
(scalance)(speed-test)# bandwidth 100
(scalance)(speed-test)# time-interval 600
(scalance)(speed-test)# window 1
(scalance)(speed-test)# end
(scalance)(speed-test)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode and speed test configuration sub-mode.
4.16.238 speed test <server>
Description
This command enables the user to run a speed test on the Iperf server at any point in time.
The speed test configuration is not saved and can be executed only once.