CLI Commands
4.16 S
SCALANCE W1750D CLI
626 Function Manual, 03/2019, C79000-G8976-C452-04
Syntax
speed-test {<server> <protocol> [<bandwidth> | <include-reverse> | <omit> |
<parallel> | <sec- to-measure> | <server-port> | <window>]}
Parameter
Description
Range
Default
server
Enter the IP address of the Iperf server on
which the speed test needs to be run.
protocol
[<tcp>|<udp>]
Enter the protocol type used for executing the
speed test.
tcp
bandwidth
<bandwidth>
Enter the bandwidth length in Mbps.
include-reverse
The direction of traffic is reversed and sent
from the server to the client. This option ena-
bles Iperf to run the speed test for an extended
duration.
omit
Enter the number of initial seconds to omit.
1-5
parallel
Enter the number of parallel client streams.
1-30
sec-to-measure
<secs>
Specify a duration (in secs) for the speed test. 0-20 secs 10 secs
server-port
<port>
Enter the server port that the client needs to
connect to execute the speed test.
5201
window
Indicates the TCP window size or socket buffer
size sent to the server while run- ning speed
test.
64000
16384000
Usage Guidelines
Use this command to run a speed test on the Iperf server at any instant.
Example
The following example runs a speed test on the Iperf server:
(scalance)# speed-test 10.17.138.2 udp bandwidth 100 sec-to-measure 20 server-port
5201
parallel 12 omit 2 window 1
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode