CLI Commands
4.9 I
SCALANCE W1750D CLI
170 Function Manual, 03/2019, C79000-G8976-C452-04
4.9.5 inbound-firewall
Description
This command configures inbound firewall rules based on the source subnet.
Syntax
inbound-firewall
rule <subnet> <smask> <dest> <mask> <match/invert> <protocol> <sport> <eport>
{permit|deny|src-nat|dst-nat ip <IP-address> <port>}[<option1....option9>]
no…
Parameter
Description
Range
Default
inbound-firewall
Opens the inbound firewall configuration mode.
rule
Creates an access rule.
You can create up to 128 access rules. However,
it is recommended to delete any existing configu-
ration and apply changes at regular intervals.
<subnet>
Allows you to specify the source subnet IP
address
<smask>
Specifies the subnet mask of the source IP
address.
<dest>
Allows you to specify the destination IP address.
<mask>
Specifies the subnet mask for the destination IP
address.
<match/invert>
match
Indicates if the rule specific to the
destination IP address and subnet mask
matches the value specified for protocol.
invert
Indicates if the rule allows or denies
traffic with an exception to the specified desti-
nation IP address and subnet mask.
match invert
<protocol>
Configures any of the following:
Protocol number between 0-255
any: any protocol
tcp: Transmission Control Protocol
udp: User Datagram Protocol
1-255
<sport>
Specifies the starting port number from which the
rule applies.
1-65534
<eport>
Specifies the ending port number until which the
rule applies
1-65534
dst-nat
Allows the AP to perform destination NAT on
packets.