Example
The following example configures an IoT transport profile:
(scalance)(config)# iot transportProfile sample
(scalance)(IoT Data Profile "sample")# endpointURL
https://edit.meridianapps.com/api/beacons/manage
(scalance)(IoT Transport Profile "sample")# endpointType Meridian-Beacon-Management
(scalance)(IoT Transport Profile "sample")# payloadContent managed-beacons
(scalance)(IoT Transport Profile "sample")# transportInterval 300
(scalance)(IoT Transport Profile "sample")# endpointToken
MzkxMTZlMWYtYTgzYS00YWUxLTkzYWEtYjQyNzE1MGMyMjAxOjBiZWJjYWViLTRjNjItNGEwNC1hMGIyLWYzZ
TM5ZDFlNGVkNg==
(scalance)(IoT Transport Profile "sample")# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms Configuration mode and iot transport profile con-
figuration sub- mode.
4.9.8 iot usetransportProfile
Description
This command sets an IoT management server profile on an Scalance W network. You can
set up to two management server profiles.
Syntax
iot usetransportProfile <profile>
Parameter
Description
<profile>
Type of IoT management server profile.
Example
The following example sets an IoT transport profile:
(scalance)(config)# iot usetransportProfile sample
(scalance)(config)# end