CLI Commands
4.19 V
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
659
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.19.13 vpn reconnect-time-on-failure
Description
This command defines a period after which the VPN connection can be reestablished when
the primary VPN tunnel fails.
Syntax
vpn reconnect-time-on-failover <down-time>
no…
Parameter
Description
vpn reconnect-time-on-failover
<down-time>
Configures a time period in minutes after which the VPN is
reconnected when the primary VPN tunnel fails.
no…
Removes the configuration.
Usage Guidelines
Use this command to configure a time period for reestablishing VPN connections. When
configured, the AP reconnects the user session when the interval specified for this command
expires.
Example
The following example configures a VPN reconnection duration:
(scalance)(config)# vpn reconnect-time-on-failover 20
(scalance)(config)# end
(scalance)# commit apply