CLI Commands
4.3 C
SCALANCE W1750D CLI
72 Function Manual, 03/2019, C79000-G8976-C452-04
ui
Parameter
Description
airwaveca
Clears the Airwave CA certificate on the AP.
ap1x
Clears the user certificate used for TLS based 802.1x authentication of
the AP.
ap1xca
Clears CA certificate used for 802.1x authentication of the AP against its
uplink wired ports.
ca
Clears the CA certificates.
clearpassca
Clears the ClearPass Policy Manager CA.
cp
Clears the captive portal server certificate.
default [clearpassca]
Clears all the default ClearPass Policy Manager CA.
radsec
Clears the RadSec server certificate.
radsecca
Clears the RadSec CA certificate.
server
Clears all server certificates.
ui
Clears the WebUI certificate.
Usage Guidelines
Use this command to clear the certificates from the AP database.
Example
The following command shows an example for clearing server certificates:
(scalance)# clear-cert server
Command Information
AP Platform
Command Mode
All platforms
Privileged EXEC mode
4.3.8 clock set
Description
This command sets the date and time on the AP system clock.