CLI Commands
4.10 L
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
193
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.10.4 loginsession
Description
This command configures the management session (Telnet or SSH) to remain active without
any user activity.
Syntax
loginsession timeout <val>
Parameter
Description
Range
Default
timeout
Number of seconds or minutes that a
management session remains active
without any user activity.
5 ... 60 minutes or
1 ... 3600 sec-
onds, 0 to disable
5 minutes
Usage Guidelines
The management user must re-login to the AP after a Telnet or SSH session times out. If
you set the timeout value to 0, sessions do not time out.
Example
The following example configures management sessions on the AP to not time out:
(scalance)(config) # loginsession timeout 0
(scalance)(config) # end
(scalance) # commit apply