EasyManua.ls Logo

Siemens SCALANCE W1750D CLI - Clock Timezone; Cluster-Security

Siemens SCALANCE W1750D CLI
762 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Commands
4.3 C
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
75
4.3.10 clock timezone
Description
This command sets the timezone on an AP.
Syntax
clock timezone <name> <hour-offset> <minute-offset>
no…
Parameter
Description
Range
clock timezone
<name>
Configures the required timezone. All supported timezones
<hour-offset>
Specifies the hours offset from the UTC.
<minute-offset>
Specifies the hours offset from the UTC.
no…
Removes the timezone configuration.
Usage Guidelines
Use this command to set the timezone on an AP.
Example
The following example configures the PST timezone:
(scalance) (config)# clock timezone PST -8 0
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.3.11 cluster-security
Description
This command enables cluster security in DTLS mode and also provides an option for users
to allow or deny a DTLS connection for low assurance APs.