CLI Commands
4.16 S
SCALANCE W1750D CLI
630 Function Manual, 03/2019, C79000-G8976-C452-04
4.16.243 syslog-level
Description
This command configures syslog facility levels. Syslog Facility is an information field
associated with a syslog message.
Syntax
syslog-level <level> {ap-debug|network|security|system|user|user-debug|wireless}
no...
Parameter
Description
Range
Default
syslog-level
<level>
Configures the Syslog facility level.
You can configure any of the following log-
ging levels:
EmergencyPanic conditions that occur
when the system becomes unusable.
Alert—Any condition requiring immediate
attention and correction.
CriticalAny critical conditions such as a
hard drive error.
Errors—Error conditions.
WarningWarning messages.
NoticeSignificant events of a non-critical
and normal nature. The default value for all
Syslog facilities.
InformationalMessages of general interest
to system users.
DebugMessages containing information
useful for debugging.
Emergency,
Alert, Critical,
Errors, Warn-
ing, Notice,
Informational,
Debug
Notice
ap-debug
Generates a log for the AP device for debugging
purposes.
network
Generates a log when there is a change in the
network, for example, when a new AP is added
to a network.
security
Generates a log for network security, for exam-
ple, when a client connects using wrong pass-
word.
system
Generates a log about the system configuration
and status.
user
Generates a log for the AP clients.
user-debug
Generates a detailed log about the clients for
debugging purposes.
wireless
Generates a log about radio configuration.
no…
Removes the configuration.