The following example prevents a non-DTLS slave AP from joining a DTLS enabled cluster:
(scalance)(config)# cluster-security
(scalance)(cluster-security)# disallow-non-dtls-slaves
Command Information
AP Platform
Command Mode
All platforms
Configuration and configuration sub-modes
4.3.12 cluster-security logging
Description
This command allows you to set per module logging levels and retrieve the debugging logs
on a one-time basis.
Syntax
cluster-security logging module <module_name> log-level <level>
Parameter
Description
Range
cluster-security
logging
Allows you to change the per module logging level for cluster
security
module <mod-
ule_name>
Allows you to set the following core modules for debugging.
peer
The peer module helps in logging the connection
initiation, renegotiation, collision, and active connection up-
dates.
conn
The connection module helps in logging connection
creation, establishment, data transfer, and maintenance
logs.
mcap
The message capture module logs the messages
received and sent to the socket.
peer
conn
mcap
log-level <lev-
el>
Allows you to set a log level.
Set the log-level to debug to log only the control messages.
Set the log level to debug1 to log both control and data
messages.
debug
debug1
Usage Guidelines
Use this command to change the per module logging level of cluster security.