CLI Commands
4.9 I
SCALANCE W1750D CLI
174 Function Manual, 03/2019, C79000-G8976-C452-04
uuidFilter
password <password>
payloadContent {managed-beacons | managed-tags | zf-tags | all | enocean-sensors
| enocean- switches |
ibeacons | eddystone | unclassified}
rssiReporting <type>
uidNamespaceFilter <filter>
urlFilter <filter>
transportInterval <interval>
username <user>
no…
Parameter
Description
Range
Default
ageFilter <ageout>
Devices without recent activity will
not be reported
0 to 3600 sec-
onds
0
authenticationURL
<url>
Denotes the server URL used for
authentication.
cellSizeFilter
<cellsize>
This is a proximity filter. Devices
outside the cell will not be reported.
Size is specified in meters. Setting to
0 disables the cell size filter.
0 to 255 meters 0
endpointID <id>
Endpoint ID of the IoT management
server
endpointToken <to-
ken>
Endpoint token of the IoT manage-
ment server.