CLI Commands
4.12 N
SCALANCE W1750D CLI
208 Function Manual, 03/2019, C79000-G8976-C452-04
no…
Parameter
Description
Default
ntp-server
<Name>
Configures the IP address or the URL
(domain name) of the NTP server.
pool.ntp.org
no
Removes the configuration
Usage Guidelines
The NTP helps obtain the precise time from a server and regulate the local time in each
network element. If NTP server is not configured in the Scalance W network, an AP reboot
may lead to variation in time dat.
Example
The following command configures an NTP server for an AP:
(scalance)(config)# ntp-server <name>
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode