CLI Commands
4.15 R
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
237
Parameter
Description
<gateway>
Specify the gateway to which traffic must be routed. This IP address must
be the controller IP address on which the VPN connection is terminated.
<metric>
This is an optional field and is configures a metric for the datapath route
from source to destination. The default metric value is 15.
no…
Removes configuration settings for parameters under the
routing-profile
command.
no routing- profile
Removes the routing profile configuration.
Usage Guidelines
Use this command to configure a routing profile for a specific destination address or
destination subnet.
Example
The following example configures a routing profile:
(scalance)(config)# routing-profile
(scalance)(Routing-profile)# route 192.0.1.0 255.255.255.0 192.0.2.0 15
(scalance)(Routing-profile)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode and routing profile configuration sub-mode.