3 Teaching
3.6 Editing Instructions
3-45
149235-1CD
RE-CSO-A031
5 Change the data of additional
items or variables as required.
<Editing Additional Items>
• Changing numeric data
Move the cursor to the desired item and press [SHIFT] + the
cursor key to increase or decrease the value.
To directly input the value using Numeric keys, press [SELECT]
to display the input buffer line.
Type the value and press [ENTER]. The value on the input
buffer line is changed.
• Adding, modifying, or deleting an item
To add, modify, or delete an additional item, move the cursor to
the instruction on the input buffer line and press [SELECT]. The
DETAIL EDIT window appears.
To add an item, move the cursor to “UNUSED” and press
[SELECT]. The selection dialog box appears.
Move the cursor to the desired item and press [SELECT].
To delete an item, move the cursor to the item to be deleted and
select “UNUSED.”
Operation Explanation
PULSE OT#( 2 )
PULSE OT#( )
OUTPUT NO.=
Short CutMain Menu
OUTPUT NO.
TIME
DETAIL EDIT
PULSE
OT#( ) 2
UNUSED
DATA EDIT DISPLAY UTILITY
PULSE OT#(2)
Short Cut
Main Menu
OUTPUT NO.
TIME
DETAIL EDIT
PULSE
OT#( ) 2
DATA EDIT
DISPLAY
UTILITY
PULSE OT#(2)
T=
UNUSED
109 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C