9 Arc Welding Application
9.4 Registering Arc Welding Instructions
9-34
149235-1CD
RE-CSO-A031
6 Set the condition set. Specify the number for the condition set (0 or 1). Move the cursor
to the ACOND number at the condition set, and press [SELECT].
Type the file number using the Numeric keys and press [ENTER].
*Select 1 for standard arc welding (when the enhanced welding
condition file function is not used).
*When the enhanced welding condition file function is used, either
one of the “start condition” or “main condition” in the condition
file can be specified by selecting the condition set number.
ACOND=0 : Sets the welding current and voltage which are
specified in the “start condition”.
ACOND=1 : Sets the welding current and voltage which are
specified in the “main condition”.
7 Press [ENTER]. The set contents are displayed in the input buffer line.
Press [ENTER]. The set contents are registered in the job.
Press [CANCEL] to return to the JOB CONTENT window when
the set contents are not to be registered.
Operation Explanation
DATA
EDIT
DISPLAY
UTILITY
DETAIL EDIT
ARCSET
SET METHOD
CONDITION SET
: ASF#()
10
: ACOND=1
JOB
EDIT
DISPLAY
UTILITY
Main Menu ShortCut
! Turn on servo power
JOB CONTENT
JOB NAME: WORK A
ARCSET ASF# (10) ACOND=1
TOOL: 00
CONTROL GROUP: R1
STEP NO: 0003
0006 MOVL V=100
0007 MOVL V=100
0008 ARCSET ASF#(10) ACOND=1
0009 MOVL V=100
0010 ARCOF AC=100 AVP=100 ANTSTK
0011 MOVJ VJ=5.00
0012 MOVJ VJ=5.00
0013 MOVJ VJ=5.00
0014 END
JOB
EDIT
DISPLAY
UTILITY
Main Menu ShortCut
! Turn on servo power
JOB CONTENT
JOB NAME: WORK A
ARCSET
TOOL: 00
CONTROL GROUP: R1
STEP NO: 0003
0006 MOVL V=100
0007 MOVL V=100
0008 ARCSET
0009 MOVL V=100
0010 ARCOF AC=100 AVP=100 ANTSTK
0011 MOVJ VJ=5.00
0012 MOVJ VJ=5.00
0013 MOVJ VJ=5.00
0014 END