Xen IPK Programming Manual
Section 5, Function Timer Chart DRAFT 3 Chapter 1 – 523
Doc. No.: 8194 - Release 2.0
December 2004
Delayed Ringing
Timer Assignment
(ICM)
1-2-26
Specify the time for delayed
ringing on internal calls.
0 sec. 10 sec. 99 sec.
PS Out of Area
Timer Selection*
1-2-30
Assigns Out of Area PS Timer
00 sec. 12 sec. 99 sec.
Bounce Protect
Time Selection
1-3-01
Specify the time before a valid
hookflash is detected from a
Single Line Telephone or Voice
Mail System.
0 ms. 300 ms. 1500 ms.
First Digit PBR
Release Timer
Selection
1-3-03
Specify the time that a receiver is
connected when a DTMF Single
Line Telephone user is dialling.
10 sec. 10 sec. 60 sec.
Hookflash Start
Time Selection
1-3-05
Specify a minimum hookflash
duration for a Single Line
Telephone to receive a second
dial tone.
40 ms. 290 ms. 790 ms.
Hookflash End
Time Selection
1-3-06
Specify a maximum duration from
a Single Line Telephone to receive
a second dial tone (HT =
Hookflash Start Time).
HST + 0 ms. HST + 700
ms.
HST + 1500
ms.
Voice Mail DTMF
Delay Timer
Selection
1-3-08
Specify the delay time before
DTMF tones are sent to the VMI
port.
0 sec. 1 sec. 8 sec.
Voice Mail
Disconnect Time
Selection
1-3-09
Specify the sending time of a
disconnect signal that is sent to
the connected equipment.
.5 sec. 1.5 sec. 3.5 sec.
Voice Mail DTMF
Duration/Interdigit
Time Selection
1-3-10
Specify the DTMF duration/
interdigit time for voice mail.
60/70 ms. 110/80 ms. 810/190 ms.
Tandem Transfer
Automatic
Disconnect Timer
Selection
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
30 min. 1 hr. 3 hr.
Tandem Transfer
Automatic
Disconnect Timer
Selection*
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
000 min. 060 min. 999 min.
Automated
Attendant First Digit
PBR Release Timer
Selection
1-4-01
Specify the PBR connection time
to the Automated Attendant trunk
to receive the DTMF signal from
the calling party before
automatically disconnecting.
5 sec. 20 sec. 60 sec.
Table 1-3: Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum Default Maximum