Xen IPK Programming Manual
Section 5, Function Timer Chart DRAFT 3 Chapter 1 – 525
Doc. No.: 8194 - Release 2.0
December 2004
PBR Interdigit
Release Timer
Selection
1-8-10
Specify the interdigit release time
for the PBR.
3 sec. 7 sec. 10 sec.
System Refresh
Timer Assignment
1-8-11
Assign the system refresh time.
No Refresh 4 hr. 24 hrs.
VRS Message
Recording Time
Selection
1-8-12
Specify the time length and
number of messages for each
VRS channel
15 sec. 15 sec. 120 sec.
ACD Hunt Timer
1-8-40
Assigns the time value for hunting
among ACD/UCD agents that do
not answer.
10 sec. 10 sec. No Limit
Trunk DTMF
Duration/Interdigit
Selection
3-15
Specify the tone duration and
interdigit time of DTMF signals
(Expressed as duration/interdigit
time).
60/70 ms. 110/80 ms. 810/190 ms.
Tie Line Prepause
Time Selection
3-16
Specify the prepause time for
when the originating side can
send dial pulse or DTMF to a
distant system.
0 sec. 0 sec. 13 sec.
Tie line Answer
Detect Time
Selection
3-17
Specify the duration between the
time when the receiving system
answers and the time when it is
recognised as an answer.
0 ms. 520 ms. 1950 ms.
Tie Line Release
Detect Time
Selection
3-18
Specify the duration between the
circuit disconnection detection on
the Tie line on the distant system
side and the time it is recognised
as Tie Line Release.
0 ms. 520 ms. 1950 ms.
Tie Line/CO/PBX
Incoming Signal
Detect Time
Selection
3-19
Specify the time between the
detection of an incoming signal
from another Xen system and the
time when the acknowledgment
signal is sent (Expressed as Wink
Start/Delay/COI in ms.).
0/0/5 520/120/200 1950/450/800
Tie Line Loop Off-
Guard Time
Selection
3-20
Assign loop off-guard protection to
prevent noise that may cause the
system to be unable to answer an
incoming Tie line.
0 sec. 2 sec. 13 sec.
Tie Line Length of
Wink Signal
Selection
3-21
Specify the time between the
incoming signal detection from
another Xen system and when the
acknowledgment signal is sent
out.
30 ms. 180 ms. 480 ms.
Table 1-3: Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum Default Maximum