Syntax
time-range <name> {absolute start <startday> <starttime> end <endday> <endtime>|
periodic {{daily | weekday |weekend} <starttime> to <endtime> | <startday <starttime>
to <endday> <endtime>}
no time-range <name>
Command/Parameter
Description
name
Enter the profile name for the time range profile.
absolute start
{<startdate>
<starttime>} end
{<enddate>
<endtime>}
The SSID is made available only during the specified date and time
range. Configure the following time range parameters:
startdayEnter the start date in the mm/dd/yyyy format.
tarttimeEnter the start time in the hh:mm format.
enddayEnter the end date in the mm/dd/yyyy format.
endtimeEnter the end time in the hh:mm format.
periodic {<startday>
<starttime>} to {<endday>
<endtime>}
The availability of the SSID will be periodically changed based on
the time range set in the profile. Configure the following time range
parameters:
startdaySpecify any day of the week from Monday to Sunday
starttimeEnter the start time in the hh:mm format.
enddayEnter the end day for the time range profile.
endtime—Enter the end time in the hh:mm format.
periodic <daily> [<start-
time> to <endtime>]
dailyThe time range profile is applied on the SSID on a daily
basis.
starttimeEnter the start time in the hh:mm format.
endtimeEnter the end time in the hh:mm format.
periodic <weekday>
[<starttime> to <endtime>]
weekdayThe time range profile is applied only during the
weekday
starttimeEnter the start time in the hh:mm format.
endtimeEnter the end time in the hh:mm format.
periodic <weekend>
[<starttime> to <endtime>]
weekendThe time range profile is applied only during the
weekend.
starttimeEnter the start time in the hh:mm format.
endtimeEnter the end time in the hh:mm format.
no time-range <name>
Removes the time range configuration.
Usage Guidelines
Use this command to create a time range profile using the SCALANCE W CLI. You can
create an absolute time profile to execute once during a specific date and time configured in
the profile or create a periodic profile to execute at regular intervals based on the periodicity
specified in the configuration. These time based profiles can be applied to existing SSIDs in
the AP.