Example
The following example creates an absolute time range profile :
(scalance)
(config) # time-range test1234 absolute start 10/20/2013 10:40 end
10/20/2015 10:50
The following example creates a periodic time range profile that executes on the specified
day of the week:
(scalance) (config) # time-range test1234 periodic monday 10:40 to tuesday 10:50
The following example creates a periodic time range profile that executes daily:
(scalance) (config) # time-range testhshs12 periodic daily 10:20 to 10:35
The following example creates a periodic time range profile that executes during the
weekday:
(scalance) (config) # time-range test123 periodic weekday 10:20 to 10:35
The following example creates a periodic time range profile that executes during the
weekend:
(scalance) (config) # time-range test12 periodic weekend 10:20 to 10:30
The following example removes the time range configuration:
(scalance) (config) # no time-range testhshs12
Command Information
AP Platform
Command Mode
All platforms
Configuration mode.