EasyManuals Logo

Fujitsu PRIMERGY TX2560 M2 Upgrade And Maintenance Manual

Fujitsu PRIMERGY TX2560 M2
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
145
Power supply unit (PSU)
6.1.1 PSU configurations
Figure 63: Types of PSUs
V CAUTION!
PSUs automatically adjust to any mains input voltage within a certain
range. You may only operate the server if its rated voltage range
corresponds to the local mains voltage. Please note that the offered PSU
types support different mains input voltage ranges.
I
All different PSUs can be installed, removed or replaced in the same way.
6.1.2 Assembly rules
– Mixed assembly of hot-plug PSUs with different power ratings (450 W,
800 W and 1200 W) is not supported.
– Mixed assembly of different 800 W hot-plug PSUs (Platinum and Titanium)
is not supported.
– PSU bay 1 always needs to be equipped with a PSU.
– Always install a dummy module into the unused PSU slot to comply with
applicable EMC regulations and satisfy cooling requirements.
Pos. PSU type Mains input
voltage range
Power class
1 PSU 450 W (Platinum) 100 V to 240 V 1
2 PSU 800 W (Platinum) 100 V to 240 V
2
3 PSU 800 W (Titanium) 200 V to 240 V
4 PSU 1200 W (Platinum)
100 V to 120 V /
200 V to 240 V
3

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2560 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2560 M2 and is the answer not in the manual?

Fujitsu PRIMERGY TX2560 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX2560 M2
CategoryServer
LanguageEnglish

Related product manuals