TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
145
Power supply unit (PSU)
6.1.1 PSU configurations
Figure 63: Types of PSUs
V CAUTION!
PSUs automatically adjust to any mains input voltage within a certain
range. You may only operate the server if its rated voltage range
corresponds to the local mains voltage. Please note that the offered PSU
types support different mains input voltage ranges.
I
All different PSUs can be installed, removed or replaced in the same way.
6.1.2 Assembly rules
Mixed assembly of hot-plug PSUs with different power ratings (450 W,
800 W and 1200 W) is not supported.
Mixed assembly of different 800 W hot-plug PSUs (Platinum and Titanium)
is not supported.
PSU bay 1 always needs to be equipped with a PSU.
Always install a dummy module into the unused PSU slot to comply with
applicable EMC regulations and satisfy cooling requirements.
Pos. PSU type Mains input
voltage range
Power class
1 PSU 450 W (Platinum) 100 V to 240 V 1
2 PSU 800 W (Platinum) 100 V to 240 V
2
3 PSU 800 W (Titanium) 200 V to 240 V
4 PSU 1200 W (Platinum)
100 V to 120 V /
200 V to 240 V
3