Upgrade and Maintenance Manual TX2560 M2 / RX2560 M2
Processor (CPU)
11.4 Upgrading or replacing CPUs
V CAUTION!
CPUs are extremely sensitive to electrostatic discharge and must be
handled with care. After a CPU has been removed from its protective
sleeve or from its socket, place it upside down on a nonconducting,
antistatic surface. Never push a CPU over a surface.
11.4.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 111
Ê
"Disabling SVOM boot watchdog functionality" on page 112
Ê
"Locating the defective server" on page 55 (if applicable)
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
Ê
"Removing the system air duct" on page 91
Ê
"Removing heat sinks" on page 387
11.4.2 Upgrading or replacing a CPU
11.4.2.1 Removing the CPU
Ê
Remove the CPU as described in section "Removing a CPU" on page 377.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver
– nut driver size 6mm

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2560 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2560 M2 and is the answer not in the manual?

Fujitsu PRIMERGY TX2560 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX2560 M2
CategoryServer
LanguageEnglish

Related product manuals