EasyManuals Logo

Fujitsu PRIMERGY TX2560 M2 Upgrade And Maintenance Manual

Fujitsu PRIMERGY TX2560 M2
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #416 background imageLoading...
Page #416 background image
416
Upgrade and Maintenance Manual TX2560 M2 / RX2560 M2
Accessible drives
12.5.3 Replacing a slimline ODD or LSD
12.5.3.1 Preliminary steps
Ê
"Locating the defective server" on page 55
Ê
"Removing backup and optical disk media" on page 114
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
I
Removing the front cover is not required in order to replace the
slimline ODD or LSD in the Multibay box.
Ê
"Removing the system air duct" on page 91
Ê
"Removing the system fan holder" on page 93
Ê
"Removing the Multibay box" on page 411
12.5.3.2 Removing the defective slimline ODD
Ê
Remove the slimline ODD from the Multibay box as described in section
"Removing the slimline ODD from the Multibay box" on page 412.
12.5.3.3 Removing the defective LSD module
Ê
Remove the LSD module from the Multibay box as described in section
"Removing the LSD module from the Multibay box" on page 414.
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver
– Slotted screw driver (for bending in or out accessible drive
mounting brackets)

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2560 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2560 M2 and is the answer not in the manual?

Fujitsu PRIMERGY TX2560 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX2560 M2
CategoryServer
LanguageEnglish

Related product manuals