EasyManua.ls Logo

Fujitsu PRIMERGY TX2560 M2

Fujitsu PRIMERGY TX2560 M2
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176
Upgrade and Maintenance Manual TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the RAID array will be lost when deleting
a RAID array! Be sure to back up your data before deleting a RAID
array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê
When working on a tower server, open the HDD bay cover as described in
section "Removing accessible drive and HDD bay covers" on page 71.
7.2.11.2 Removing a 2.5-inch HDD/SSD module
Ê
Pinch the green locking clips and open the locking lever (see figure 88 on
page 174).
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait about 30 seconds to allow the HDD to spin down.
I
This is not necessary when removing an SSD.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê
Pull the HDD/SSD module completely out of its bay.