TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
127
Basic software procedures
Windows Server 2012 and above:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
Ê
Choose the
Memory
status tab.
Ê
Select the memory module which shows the pre-failure status.
Ê
Click on
Reset Status
.
I
The
Reset Status
button will only be available if the selected memory
module contains errors.
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line interface (Linux/VMware only)
The memory error counter can be reset using the
meclear
utility which is part
of the ServerView agents for Linux.
I meclear
(Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it has
been replaced.
For further details, please refer to the
meclear
manual pages.
Ê
Log in as root.
Ê
Enter the command below, followed by
[ENTER]
:
/usr/sbin/meclear
Ê
Select the number of a memory module with a status other than "OK" or
"Not available".
Ê
Repeat the step above until all memory modules show the "OK" status.
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2 Processors
ServerView Operations Manager may report a defective processor in case of a
critical error.
I Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.