TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
457
System board and components
Ê
Download the desired ESXi Recovery CD ISO image, listed under
Tools
.
Ê
Unpack and burn the image to a CD.
Ê
Ensure that no other USB storage device is connected to the server beside
the UFM.
Ê
Insert the Recovery Tools CD into your CD/DVD drive and reboot the server.
The server should now boot from the Recovery Tools CD.
Ê
Follow the on-screen instructions to initiate the installation.
After the flash process is complete, you will be asked to reboot the system.
14.3.2 Removing the UFM
14.3.2.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 111
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
Ê
If applicable, remove an expansion card in slot 1 as described in section
"Removing expansion cards from standard slots" on page 300.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2560 M2