SPECIAL PROCEDURES April, 2007
4-8
Code
Error Problem Recovery
ITB misaligned Reinstall ITB.
SP2153 023 set to 1 (OFF). Set SP2153 023 to 0 (ON).
The settings of sensor lights 1, 2, 3 are different from
the default setting, which is 2050. (These settings are
done with SP2153 020~022.)
Dirty, abnormal images.
Output Pattern 1, 18, or 20 with SP2109 002 and
check the images.
61 Time out of detecting MUSIC
pattern.
Connector loose.
Connector dirty.
Harness defective.
Other
Check the ID sensor and its connection.