August, 2006 ARDF INPUT/OUTPUT CHECK
5-203
5.7.2 ADF OUTPUT CHECK: SP6008
1. Open SP mode SP6008.
2. Select the SP number that corresponds to the component you wish to check.
(Refer to the table below.)
3. Press On then press Off to test the selected item. You cannot exit and close
this display until you click Off to switch off the output check currently executing.
6008 ADF Output Chk ADF Output Check
Turns on the ADF electrical components individually for testing. Select the
component to test, then press the "ON" button. Besure to press the "OFF" button
as soon as you hear the component turn on.
001